BSGVF - CHEMICAL RESISTANT WASH PRIMER-GREEN CURING (SUPDAT)

Product Identification

Product ID:CHEMICAL RESISTANT WASH PRIMER-GREEN CURING (SUPDAT)
MSDS Date:01/01/1991
FSC:8010
NIIN:00N040901
Kit Part:Y
MSDS Number: BSGVF

Responsible Party
CROWN METRO AEROSPACE COATINGS INC
GREENVILLE, SC 29606
US

Emergency Phone: 803-277-1870

Info Phone: 803-277-1870

Cage: CROME

Contractor
CROWN METRO AEROSPACE COATINGS INC
5695 GREENVILLE, SC 29606 US

Telephone: 803-277-1870

Cage: CROME

Ingredients

CURING SOLUTION (CONSISTING OF INGREDIENTS 2-4)

RTECS: 9999999ZZ


PHOSPHORIC ACID (SARA III)

CAS: 7664-38-2

RTECS: TB6300000

Fraction By Weight: 5%

OSHA PEL 1 MG/M3;3 STEL

ACGIH TLV: 1 MG/M3;3 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


90 @ 20F.

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 15%

OSHA PEL 400 PPM;500 STEL

ACGIH TLV: 400 PPM/500 STEL


17 @ 20F.

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CAN CAUSE IRRITATION TO SKIN, EYES AND
RESPIRATORY TRACT. SYMPTOMS MAY BE WATERING OF EYES, DRYNESS OF
THROAT, COUGHING, HEADACHE, TIGHTNESS IN CHEST OR BURNING
SENSATION. ALLERGIC REACTIONS MAY OCCUR IN SOME INDIVIDUALS.
HEADACHE, DIZZINESS OR NAUSEA MAY BE EXPERIENCED BY SOME AS A
RESULT OF EXPOSURE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:TO SOLVENTS.
Medical Cond Aggravated by Exposure:PERSONS WITH ASTHMATIC TYPE
CONDITIONS, CHRONIC BRONCHITIS OR OTHER CHRONIC RESPIRATORY DISEASE
OR RECURRENT SKIN ECZEMA OR SENSITIZATION SHOULD BE EXCLUDED FROM
WORKING WITH THIS PRODUCT.

First Aid

First Aid:EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CALL MD.
SKIN:WASH AFFECTED AREA WITH SOAP & WATER. REMOVE CONTAMINATED
CLOTHING. CALL MD. INHAL:REMOVE TO FRESH AIR. CALL MD. INGEST:DRINK
WATER TO DILUT E. DO NOT INDUCE VOMITING. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:54F,12.2C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, WATER FOG OR NFPA CLASS B
EXTINGUISHERS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE
PREF. WATER MAY BE USED TO COOL (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, SPARKS, ELEC EQUIP, & OPEN FLAME. CLSD CNTNRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. APPLIC TO HOT (SUPP DATA)

Accidental Release

Spill Release Procedures:EVACUATE NON-ESSENTIAL PERSONNEL. REMOVE ALL
IGNIT SOURCES (SPARKS, FLAMES, HOT SURFACES). VENTILATE AREA. EQUIP
CLEAN-UP CREW WITH NIOSH/MSHA APPROVED SCBA. DIKE SPILL. COVER WITH
SAWDUST, VERMICULIT E OR FULLERS EARTH. COLLECT MATL IN OPEN
CNTNRS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 100F.STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED TO COMPLY WITH OSHA 1910.106. KEEP
CONTAINERS CLOSED AND UPRIGHT TO PVNT LEAKAGE.
Other Precautions:DO NOT STORE OR USE NEAR HEAT, SPARKS OR FLAMES.
AVOID PROLONGED OR REPEATED CONTACT WITH VAPOR OR SPRAY MIST DURING
APPLICATION OR CURING.

Exposure Controls

Respiratory Protection:ALL RESPIRATORS MUST BE NIOSH/MSHA APPROVED. IN
OUTDOOR/OPEN AREAS USE MECH FILTER RESP. IN RESTRICTED VENT AREAS,
USE CHEM/MECH FILTERS TO REMOVE VAPORS & PARTICULATES. IN CONFINED
AREAS USE AIR LINE TYPE RESPIRATORS OR HOODS.
Ventilation:MUST BE SUFFICIENT IN VOLUME AND PATTERN TO KEEP
CONTAMINANT CONCENTRATION BELOW TLV OR PEL.
Protective Gloves:BUTYL RUBBER RECOMMENDED.
Eye Protection:ANSI APRV CHEM WORK GOG&FL (OTR PROT EQT
Other Protective Equipment:PROTECTIVE CREAMS WHERE SKIN CONTACT IS
LIKELY. CHEMICAL RESISTANT BOOTS. EYE PROT: LGTH FCSHLD .
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING BATHROOM.
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
MFR PT NO/TRADE NAME:SOLUTION PART B, AC-102. FIRE FIGHT PROC:CLSD
CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT OR EXPLO WHEN
EXPOSED TO EXTREME HEAT. EXPLO HAZ:SURFS REQS SPECIAL PRECS. DURING
EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY
NOT BE IMMEDIATELY APPARENT. GET MD.

Chemical Properties

Boiling Pt:B.P. Text:>180F,>82C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.895
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:90

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:TEMPERATURES ABOVE MAXIMUM STORAGE
TEMPERATURE. AVOID EXPOSURE TO HEAT, SPARKS, OR OPEN FLAMES.
Hazardous Decomposition Products:BY FIRE:CO, CO*2, AND NITROGEN OXIDES.

Disposal

Waste Disposal Methods:CONFORM TO FEDERAL, STATE AND LOCAL REGULATIONS.
EMPTY CONTAINERS MUST BE HANDLED CAREFULLY DUE TO PRODUCT RESIDUE
AND FLAMMABLE SOLVENT VAPOR.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.